Nutrient Separating Baffle Box
The 2nd generation Baffle Box design removes sediment,
foliage and litter without head loss. It separates nutrients from
stormwater and prevents bacterial build-up. Sediments settle to
the bottom. The box can be made of either concrete construction
or fiberlass in any size. In addition, it easily retrofits to existing
pipe and is easy to clean.
|
Schematic Drawing - During Storm Event
- The inflow pipe is the same size as the ouflow.
- Turbulence deflectors prevent captured sediment from re-suspending.
- Hydrocarbons collect in front of skimmer and are absorbed
by Storm Boom.
|
Patented |

Patented |
Schematic Drawing - After Storm Event
- Nutrient pollutant load is not lost to static water and
flushed out at the next storm event.
- Separating organic matter from the static water prevents
bacterial buildup.
To view installation photos of Nutrient Separating
Baffle Boxes - CLICK
HERE. |
Size Determination
Because the entire flow is always treated and head
loss is so minimal, determining the appropriate size of Nutrient
Separating Baffle Box for a project is more an element of pipe size
than treated cfs.
| Model # |
Inside Width |
Inside Length |
Standard Height * |
Recommended Pipe Sizes |
| 4-8 |
4' |
8' |
7' |
12"-18" |
| 5-10 |
5' |
10' |
7' |
12"-24" |
| 6-12 |
6' |
12' |
7' |
18"-36" |
| 8-12 |
8' |
12' |
8' |
36"-48" |
| 8-14 |
8" |
14' |
8' |
40"-54" |
| Custom sizes are available. |
* Height can vary
as needed. |
- Because water flow is not ducted off line for treatment,
head loss is minimal and comparable to a large square catchbasin.
Because of this, existing stormwater systems can be retrofitted
with a Nutrient Separating Baffle Box, without compromising the
original design specifications of the existing stormwater system.
- All structures are load rated for at least H-20. Standard wall
construction of the structure is 6" thick steel re-enforced
concrete. Concrete wall thickness can be thicker upon request.
- Manhold lids, hatches, and dampers to block off water flow during
servicing can be incorporated into the structure.
- Screen systems have stainless steel screens bolted into a heavy
duty aluminum framework. The screen systems are hinged to give
easy access to the lower chambers and have a wide range of adjustments
to accommodate unforeseen variables during installation.
|
Bio Clean
Environmental Services, Inc.
P.O. Box 869
Oceanside, CA 92049
| Phone: (760) 433-7640 | Fax: (760) 433-3176 | |
|
All
contents of this site are copyright © 2002-2003 Bio
Clean Environmental Services, Inc.
All Rights Reserved. Web site development by Digital
Intellect. |
|